Technical capabilities:
Four-tier indicators, mature processes, stable performance
Ⅰ:175℃,140Mpa(350F,20000+Psi)
Ⅱ:203℃,172Mpa(400F,25000+Psi)
Ⅲ:230℃,200Mpa(450F,30000+Psi)
Ⅳ:260℃,230Mpa(500F,34000+Psi)
Product Application Scope
- Suitable for petroleum exploration and well logging, primarily used for signal transmission in logging equipment.
 - Capable of withstanding water/oil pressure of 140 MPa to 230 MPa.
 
Key Technical Specifications
- Mechanical Properties
 
- Housing: High-temperature-resistant alloy
 - Insulator: High-temperature glass/ceramic
 - Contact Pins: Nickel-plated & gold-plated
 - Mechanical Lifespan: 500 mating cycles
 
- Environmental Performance
 
- Operating Temperature Range: -55°C to +230°C (or +260°C)
 - Humidity Resistance: 90%–95% RH at 40°C ± 2°C (damp conditions)
 - Application Environment: Downhole, pressure resistance >140 MPa–230 MPa
 - High-Temperature Zones: 175°C–260°C
 
- Electrical Performance (Four Grades)
 
- At Room Temperature & Atmospheric Pressure:
 - Helium Leak Rate: ≤1.0×10⁻¹⁰ Pa·m³/s
 - Insulation Resistance (DC 1000V): >3000 MΩ
 - Under Extreme Conditions:
 - 175°C & 140 MPa: No leakage after 4-hour pressure hold, insulation resistance >1000 MΩ
 - 203°C & 172 MPa: No leakage after 4-hour pressure hold, insulation resistance >1000 MΩ
 - 230°C & 200 MPa: No leakage after 4-hour pressure hold, insulation resistance >1000 MΩ
 - 260°C & 230 MPa: No leakage after 4-hour pressure hold, insulation resistance >1000 MΩ
 